I completed a diagnostic. On my arrival found system low on refrigerant. Spoke with customer and added 1.25 pounds of R22 to bring superheat from 46° down to 16°. Filter is clean and everything else seems to be working OK at this time even though unit is very old. Customer does understand this means there is a small leak somewhere and we cannot guarantee how long refrigerant will remain in the system.
I performed a diagnostic service call on an 18yr old unit that was no longer cooling the home. I replaced the compressor and the system was operational at departure.
I gave an estimate to install a Five Star 60,000 BTU up to 2.5 ton air conditioner. Included in the estimate is a 1 year free service maintenance agreement.
I gave an estimate to replace a Sun Dial gas furnace and add an air conditioner. I recommend replacing it with a Five Star 96% 60,000 BTU Gas Furnace and a Five Star 13 SEER 2 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.
I performed a diagnostic on a Nordyne gas furnace that had intermittent heat. The furnace also would not ignite. Due to significant rust on the manifold, I pulled it and cleared the ports. I tapped on the gas valves and restarted the system. The system ignited and is heating the home. I would recommend the replacement of the gas valve and manifold.
I performed a diagnostic on a Goodman gas furnace. The ignitor is cracked. The client declined replacement at this time.
I performed a diagnostic on a Goodman gas furnace. The ignitor is cracked. The client declined replacement at this time.
I found the drain line going outside frozen, causing the inducer motor housing, collector box and condensate trap to backfill with water. I wired a condensate pump into furnace power and ran vinyl tubing about 15ft to a nearby drain for washer machine. I dumped the backfilled water out of the parts, system is all good.
I found the "boom" noise the customer was hearing was coming from the extreme flame rollout the furnace was producing. The exhaust smoke coming from chimney smelled like rotten eggs. I found the heat exchanger to be bad. The customer is replacing the system.
I found the "boom" noise the customer was hearing was coming from the extreme flame rollout the furnace was producing. The exhaust smoke coming from chimney smelled like rotten eggs. I found the heat exchanger to be bad. The customer is replacing the system.
I am Performing our Five Star Tune-Up & Safety Check on a 2020 Coleman Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
I am Performing our Five Star Tune-Up & Safety Check on a 2009 Lennox Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
Upon tune inspection for 2012 Payne Furnace, found inducer capacitor tested below recommended value. Recommend it be replaced. Customer would like to hold off for now on any repairs and will give us a all if she needs anything.
Performing our Five Star Tune-Up & Safety Check on a2002 Goodman Gas Furnace . All readings were within manufacturer's specifications, unit operating properly at this time.